MSNSwitch2 Internet Enabled IP Remote Power Switch with Automatic Reboot – Control via Smartphone App or Web

Model UIS-722b is identical to Model UIS-622b but with a faster CPU.

MSNSwitch2 can power-cycle any device when Internet connectivity is lost. This remotely controlled AC power switch can automatically reboot your modem or router without anyone present.

MSNSwitch2 will automatically ping up to 7 different preset targets, which can be changed – if they are unreachable, MSNSwitch2 will power-cycle one or both AC outlets. Power cycles can also be scheduled in advance. Plus, you can control everything from your smartphone!

MSNSwitch2 is a must have for remote site equipment – Pays for itself with just 1 saved site visit!

Enterprise Grade Features

One press protect, no Internet setup required – Functional out of the box!Maintain a continuous Internet connection by resetting power outlets when Internet freezesOption to PING LAN IP or WAN IPScheduled Outlet Power Cycles – 20 On/Off at Day/Time eventsCountdown Power-Cycling – Automatically power cycle outlet power every X mins (1-1440)Heartbeat Monitoring – Reset one or both outlets if the MSNSwitch does not receive a heartbeat packetDynamic DNS Support & Remote AdminEvent Log & EMail Alerts – Notify multiple users of various eventsAdvanced Network Configuration – DHCP or static IP address, DNS servers and HTTP/HTTPS web admin interface portSave/Restore Configuration – Easily copy the configuration to multiple units

Typical MSNSwitch2 Network Setup to Restart a Modem or Router when the Internet Locks Up

MSNSwitch in Network DiagramMSNSwitch in Network Diagram

HOW IT WORKS

Plug the MSNSwitch’s power cord into a wall outlet or UPSPlug your modem & router power adapters into the MSNSwitch, typically with the modem in Outlet #1Plug an Ethernet cable between the MSNSwitch and your routerPress and hold the UIS button on the center top of the MSNSwitch until the the button glows blueNow when the MSNSwitch detects that it cannot access the Internet, it will cycle power to your modem & router

You can also use the ezDevice app, Cloud4UIS web site, or the MSNSwitch’s internal web server to adjust various settings to meet your needs such as changing how many times the MSNSwitch will restart a device, how long it takes to determine an Internet outage, or to schedule regular on-off cycles.

4 Ways to Monitor Status, Control Outlets & Configure the MSNSwitch

ezDevice IconezDevice Icon

Free ezDevice APP

ezDevice is a free smartphone app for Android and Apple iOS that can contol and manage multiple MSNSwitches (and ezOutlet’s) from a single screen. Download it from your app store.

Cloud4UIS iconCloud4UIS icon

Free Cloud4UIS.com Web Service

The free Cloud4UIS.com web service works in conjunction with MSNSwitch to allow management of your devices from any web browser.

Internal Web Server IconInternal Web Server Icon

Embedded Web Server

The MSNSwitch’s internal web server provides full access to all of the MSNSwitch’s settings and advanced features.

HTTP RESTFUL Programming APIHTTP RESTFUL Programming API

RESTful Programming API

Use your favorite programming tools to communicate with the MSNSwitch via a simple HTTP-based API.

Includes Free Subscription to the Cloud4UIS Multiple Device Remote Management Platform

Cloud4UISCloud4UIS

MSNSwitch2 is Ideal For:

Small Office or Home xDSL, Cable or 4G/5G Modem UsersIT ProfessionalsSystem IntegratorsInternet or VoIP Service ProvidersKiosks or ATM ProvidersVending Machine or Commercial Digital Displays

See the Installation Guide PDF file in the Technical Specification section of this listing for examples of the 7 ways to control the MSNSwitch.

Specifications

Model # UIS-722b Input Voltage Range 100~250 VAC, 50/60Hz – Output Voltage Matches Input Voltage Max Output Current 10A combined across both outlets Input Plug / Output Sockets Type B (US) NEMA 5-15R Fuse Type T10AH250V Ceramic Slow Blow 5×20 mm (1 spare fuse included in power inlet port) Network 10/100 Base-T, RJ45 Operating Conditions 0~60C at 10~90% RH Environmental Rating IP20 Dimensions 6.3 x 3.75 x 1.58 in (160x95x40 mm) Languages Supported English, Spanish, Chinese (Traditional), Portuguese (Brazilian), Italian, German Package Includes MSNSwitch2, Ethernet Cable, User Guide

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Customer Reviews

4.3 out of 5 stars 333

4.3 out of 5 stars 336

4.3 out of 5 stars 336

4.3 out of 5 stars 333

Price

$113.95$113.95 $91.95$91.95 $75.19$75.19 $312.95$312.95

Model #
UIS-722b EZ-72b EZ-73a UIS-801bc

# Outlets
2 1 2 2

Connectivity
Ethernet Ethernet & WiFi Ethernet & WiFi Ethernet & WiFi

Status
LEDs LEDs OLED Display LEDs

Max Current
10A 10A 2.5A 15A (13A Continuous)

Voltage
100-240 VAC @ 50/60 Hz 100-240 VAC @ 50/60 Hz 125 VAC @ 50/60 Hz 100VAC – 125VAC @ 50/60Hz

Plug/Receptacle
2x 3-Prong NEMA 5-15 1x 3-Prong NEMA 5-15 2x 2-Prong NEMA 2-15 2x 3-Prong NEMA 5-15

Cloud Management

Event Log / Email Notifications


no data
no data

IP’s Monitored
up to 7 1 1 up to 7

Monitors Internet Connectivity and Automatically Cycles One or Both Outlets When Connection is Lost + User Definable Scheduled Power Cycling
Functional Out of the Box – Single Button Press Enables Auto Reset Function with Settings Appropriate for Most Situations
Automatically Control and Reboot any Remote Electrical Equipment such as Computers, Modems, Routers, DVRs, PLCs, Industrial Computers, etc.
Configure & Control Remotely Over the Internet via ezDevice Smartphone App, Cloud4UIS Web Service, any Web Browser or its API
Pings Multiple Internet Sites to Determine Online Status – User Definable Targets & Fault Tolerance

MSNSwitch2 Web Enabled IP Distant Energy Change with Reboot – Management through Smartphone App, Cloud Service, Net Browser or API – 2 Impartial AC Energy Shops (Mannequin UIS-722T) (TAA Compliant)
MSNSwitch2 Web Enabled IP Distant Energy Change with Reboot – Management through Smartphone App, Cloud Service, Net Browser or API – 2 Impartial AC Energy Shops (Mannequin UIS-722T) (TAA Compliant)

$127.95

CyberNova Magazine
Logo
Shopping cart